Network Appliance NS0-593 certification exam is designed for individuals who want to demonstrate their advanced knowledge and skills in supporting NetApp ONTAP storage systems. NetApp Certified Support Engineer ONTAP Specialist certification is intended for support engineers who work in complex storage environments and need to troubleshoot and resolve issues related to data management, backup and recovery, and performance optimization. NS0-593 exam covers a wide range of topics, including cluster configuration, data protection, storage efficiency, and ONTAP administration.
NEW QUESTION # 25
You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size
of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and
you receive anout of apace error message on your host.
What would cause this error?
- A. The maximum number of volume constituents has been reached in the ONTAP software.
- B. All constituent volumes are full.
- C. The inode limit is exceeded in the ONTAP software.
- D. The maxdirsize Is exceeded in the ONTAP software.
Answer: C
NEW QUESTION # 26
Which two throughput elements are controlled by host applications? (Choose two.)
- A. Jitter
- B. operation size
- C. concurrency
- D. latency
Answer: A,D
NEW QUESTION # 27
A customer with an FC MetroClusterconfiguration that is running NetApp ONTAP 9.8 software experienced a
site outage and wants to know why the MetroClusler configuration did not switch over to the other site.
What are two reasons for this problem? (Choose two.)
- A. There was a failed PSU inthe switchover site.
- B. An ISL link was not operating at 16Gbps.
- C. The ISLs were down between the sites.
- D. The site had unmirrored aggregates.
Answer: A,D
NEW QUESTION # 28
A 2-node cluster hosts only NAS data UFs. Allnodes lose access to the cluster network.
Referring to the exhibit, which statement is correct?
- A. No takeover event will occur and NAS data UFs will not be accessible.
- B. All nodes in the cluster reset and NAS data UFs are not accessible after reboot.
- C. Both nodes race to takeover the other, one node will takeover the other node.
- D. NAS data UFs are accessible on only the node that has Epsilon.
Answer: B
NEW QUESTION # 29
Recently, a CIFS SVM was deployed and is working. The customer wants to use the Dynamic DNS(DDNS)
capability available in NetApp ONTAP to easily advertise both data UFs to their clients. Currently. DNS is
only responding with one data LIF. DDNS is enabled on the domain controllers.
Referring to the exhibit, which two actions should be performed to enable DDNS updates to work? (Choose
two.)
- A. Enable the -use-secure parameter for the SVM DDNS services.
- B. Remove the NFS protocol from the cifs_01 data LIF.
- C. Disable the -vserver-fqdn parameter for the SVM DDNS services.
- D. Enable the -is-enabledparameter for the SVM DDNS services
Answer: C,D
NEW QUESTION # 30
You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp
CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that
the cluster network has degraded. After troubleshooting, you determine that the errors are being generated
fromNode 2, interface e0b.
In this scenario, what should you do first to solve this problem?
- A. Replace the NetApp CN1610 switch that connects to Node 2, interface e0b.
- B. Replace both NetApp CN1610 switches.
- C. Replace the motherboard on Node 2.
- D. Replace the Twinax cable between Node 2, Interface e0b. and the NetApp CN1610 switch.
Answer: C
NEW QUESTION # 31
Your customer installed the shelf firmware for their NS224 shelf over a week ago, and the firmware has
notupgraded on shelf 1 module B. The customer wants to know what the next steps would be to get the
firmware upgraded after verifying that the shelf firmware is indeed loaded onto the system.
Which step would you perform to complete the firmware upgrade?
- A. Reseat the PSU of the shelf.
- B. Reseat the disk in Bay 0.
- C. Power cycle the shelf.
- D. Reseat the NSM100 module.
Answer: C
NEW QUESTION # 32
Your customer has deployed a two petabyte NetAppONTAP FlexGroup volume across their 4-node ONIAP
9.8 cluster. They plan to store over three billion files. They want to prevent file 10 conflicts since files are
placed into the FlexGroup volume.
In this scenario, which two NFS SVM parameters should be enabled? (Choose two.)
- A. -v4-64bit-idantifiers
- B. -v4-fsid-change
- C. -v3-64bit-identifiers
- D. -v3-fsid-change
Answer: C,D
NEW QUESTION # 33
Your customer is running a NetApp AFF A800 system with NetAppONTAP 9.8 software and states that their
NS224 shelf is not showing with the correct shelf ID. You analyze the data and the shelf shows an
identification of "1.SHFHUXXXXXXXXXX."
What is the cause of the reported Issue?
- A. A new shelf was added to the controller.
- B. The shelf had a disk replaced too quickly.
- C. The shelf was cabled Incorrectly.
- D. The shelf has been power cycled.
Answer: A
NEW QUESTION # 34
Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate
on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown
below.
Shelves with both connections via the same SAS path detected
Referring to the exhibit, which statement is correct?
- A. In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on
two paths. - B. The cables are cabled Incorrectly on the SAS stack.
- C. Active IQ Is not aware of the shelf configuration for a single-node system.
- D. This situation is normal for a FA57750 single-node system.
Answer: D
NEW QUESTION # 35
You receive the panic message shown in the exhibit.
In this scenario, which component should you troubleshoot first?
- A. the memory module in slot 1
- B. the MetroCluster FC-Vl card in slot 6
- C. the CPU
- D. the PCI card in slot 3
Answer: C
NEW QUESTION # 36
You ate connecting a Windows Server 2019 hostto ISCSI LUNs on a 4-node AFF A250 cluster running
NetApp ONIAP 9.8 software. The host is unable to connect to the target interface, and the ONTAP event log
has the message shown below.
ISCSI: network interface identifier disabled for use; incoming connection discarded
In this scenario, what is the cause of this connection issue?
- A. The WWPN was not added to the initiator group.
- B. The iSCSI service is not enabled on the interface.
- C. iSNS is not enabled on the storage virtual machine.
- D. CHAP isnot configured correctly for the specified initiator.
Answer: A
NEW QUESTION # 37
You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need
to know the storagelimits.
In this scenario, which source should be reviewed?
- A. NetApp Cloud Volumes ONTAP Release Notes
- B. Cloud Central
- C. Interoperability Matrix Tool (IMT)
- D. Hardware Universe
Answer: A
NEW QUESTION # 38
You receive the "Unable to connect to the management gateway server"error when trying to connect to a node
management IP.
In this situation, how do you determine whether core dumps are generated for the mgwd user space process?
- A. Log in to the systemshell and collect core dumps from thesystemshell.
- B. Log in to the clustershell using the node console and collect the core dumps from the clustershell.
- C. Log in to the nodeshell using the node console and collect the core dumps from the nodeshell.
- D. Log in to the service processor and collect the core dumps from the service processor.
Answer: D
NEW QUESTION # 39
You recently discovered the error message shown below in your ONTAP logs.
What should be your first action to correct this Issue?
- A. Determine the root cause behind the inconsistency before attempting any recovery procedure.
- B. Use the wafliron command against my_data_vol to solve the inconsistency on the volume.
- C. Use the storage takeover command on the storage controller that contains my_data_vol.
- D. Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol
volume.
Answer: D
NEW QUESTION # 40
Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FC
protocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reports
that the server's FC HBA port Is online, but the LUN does not show up.
Referring to the exhibit, what is the reason for this problem?
- A. The LUN Is not mapped to the correct SCSI ID.
- B. The esxserver igroup contains incorrect IQNs.
- C. The FC service has not been configured on the SVM.
- D. The zoning on the FC switches Is Incorrect.
Answer: A
NEW QUESTION # 41
A customer wants to connect a NetApp AFF A700 system to a 40GbE switch. The controllers have a 10/40G
Ethernet card in slot 4 for this purpose. The link comes up fine on node 2,but it will not come up on node 1.
You look at the AutoSupport data for the nodes in question and see the output shown in the exhibit.
What is the cause of the customer's problem?
- A. The port has an incorrect SFP inserted.
- B. The cable is plugged in upside down.
- C. The incorrect cable is used.
- D. The ports are configured for 4x10Gbit instead of 40Gbit.
Answer: D
NEW QUESTION # 42
Your customer has mounted an NFS SVM from a Linux client unci performance is very poor. The customer is
certain that they have jumbo frames enabled. They have verified an MTU of 9000 on both the Linux client and
the broadcast domain on the NetApp ONTAP 9.8 cluster.
Referring to the exhibit, which ONTAP command will help isolate a possible MTU mismatch?
- A.

- B.

- C.

- D.

Answer: B
NEW QUESTION # 43
A storage administrator reports that a monitoring toot is reporting that the storage controller reads between
90% to 93% CPU use. You run the sysstat -m command against thenode in question.
Referring to the exhibit, which statement is correct?
- A. The customer should be advised to exclude certain workflows to reduce use.
- B. High network exempt use could be a problem.
- C. The CPU Is not a first-order monitoring metric for ONTAP.
- D. You should immediately investigate further bygathering perfstat data and opening a support case.
Answer: D
NEW QUESTION # 44
Which two automation methods does NetApp ONTAP Select support? (Choose two.)
- A. REST
- B. PHP
- C. Docker
- D. Anslble
Answer: A,D
NEW QUESTION # 45
An administrator receives the following error message:
What are two causes for this error? (Choose two.)
- A. A disk is falling.
- B. An SSD disk is performing garbage collection to create a dense data layout.
- C. There is excessive SATA HDD load.
- D. There Is excessive SSD load causing the wear leveling to become unbalanced.
Answer: C,D
NEW QUESTION # 46
......
Network Appliance NS0-593 (NetApp Certified Support Engineer ONTAP Specialist) Certification Exam is designed for IT professionals who want to demonstrate their expertise in supporting NetApp storage systems running on ONTAP software. NetApp Certified Support Engineer ONTAP Specialist certification is intended for individuals who work in technical support roles and are responsible for resolving complex technical issues related to NetApp storage solutions.