EXIN CDCS Exam Syllabus Topics:
| Section | Objectives |
|---|---|
| Topic 1: Data Centre Life Cycle and Standards | - Compliance and operational governance - Data centre lifecycle management - Industry standards (ISO, ITIL, TIA-942 concepts) |
| Topic 2: Data Centre Environmental Considerations and Efficiency | - Energy efficiency metrics (e.g., PUE, DCiE) - Airflow management and thermal design - Power and cooling fundamentals |
| Topic 3: Designing and Implementing a Data Centre | - Physical infrastructure layout - Hardware and system selection - Capacity planning and scalability |
CDCS FAQ: Read Before You Register
The EXIN EPI Certified Data Centre Specialist blueprint divides into 3 domains — including Designing and Implementing a Data Centre, Data Centre Life Cycle and Standards, Data Centre Environmental Considerations and Efficiency. Those weights tell you where the points live; plan revision time in the same proportions. The full subtopic list appears above.
No formal prerequisites; recommended experience in data centre or IT infrastructure operations Eligibility rules change occasionally, so confirm them on the official page (official CDCS exam page) before booking.
Yes — the free EXIN EPI Certified Data Centre Specialist demo at LatestCram shows real questions and answers before you pay. Every purchase includes 365 days of free updates, renewable later at 50% off.
The official format: 90 minutes, 60 questions. That ratio is the real challenge, so practice pacing — time-box each question, mark the stubborn ones, and run full simulations in the LatestCram PC test engine until the clock stops being scary.
Yes:
Classroom learning ends where self-testing begins — after any course, work through the 122 practice questions for the EXIN EPI Certified Data Centre Specialist to find weak spots before the exam does.
The EXIN EPI Certified Data Centre Specialist is EXIN's official exam for the EXIN EPI Data Centre Management credential (Specialist / Advanced level). In the job market it works as portable proof of skill — more interviews, better offers. It pairs naturally with EXIN EPI Certified Data Centre Professional (CDCP), EXIN EPI Certified Data Centre Expert (CDCE).
Two promises. Delivery: payment triggers an automatic email within a minute — instant download, unlimited devices, 24/7 help if nothing arrives within 2 hours. Refund: take the corresponding CDCS exam within 60 days of purchase, and if you fail, send a scanned enrollment slip plus the official Score Report PDF within 2 days of the exam for a full refund, processed within 7 days. Excluded: exams within 3 days of purchase, candidate names that don't match the payer, and free or expired products. Prefer a swap? Exchange for two equal-value products free.
Register through the vendor's official channels:
The EXIN EPI Certified Data Centre Specialist is delivered Computer-based / proctored online or test centre exam (depending on provider) — choose whichever suits you when booking.
Varies by region (not fixed, typically set by EXIN training/exam provider) per attempt; 75% to pass. Since a retake bills the full fee again, rehearse with the 122 practice questions from LatestCram until your mock scores clear the bar with room to spare.
EXIN EPI Certified Data Centre Specialist Sample Questions:
You are allowed to use a calculator for this question. The total power consumption of the ICT equipment in a rack is 6 kW. The equipment is traditional ICT equipment with a Delta-T of approximately 11 °C / 20 °F.
Calculate the approximate CFM required to cool the equipment in the rack.
- A. Approximately 1,500 CFM
- B. Approximately 1,000 CFM
- C. Approximately 500 CFM
- D. Approximately 160 CFM
Correct Answer: B 🗳️
Explanation: Only visible for LatestCram members. You can sign-up / login (it's free).
When installing a raised floor, can we use a spirit level bar to level the floor?
- A. Yes, using a spirit level bar for raised floors higher than 40 cm is preferred.
- B. Yes, spirit level bars can be used as long as their length is longer than 60 cm/2 ft (the size of a typical raised floor tile).
- C. No, because using a spirit level bar, a measurement error will be transferred from pedestal to pedestal.
- D. Yes, but spirit level bars can only be used in the vertical plane.
Correct Answer: C 🗳️
Explanation: Only visible for LatestCram members. You can sign-up / login (it's free).
Does hot/cold aisle containment impact PUE?
- A. Yes, avoidance of mixing improves PUE
- B. No, airflow has no impact on power
- C. No, unless using virtualization
- D. Yes, but not with cooling towers
Correct Answer: A 🗳️
Explanation: Only visible for LatestCram members. You can sign-up / login (it's free).
You want to make cooling more effective by setting cold aisle temperature to 4 °C (39 °F). Is this acceptable?
- A. No, 4 °C (39 °F) is below the allowable ASHRAE range
- B. No, intake air must be exactly 20 °C (68 °F)
- C. Yes, as long as dewpoint doesn't go below -9 °C (16 °F)
- D. Yes, but only if cooling systems can maintain this continuously
Correct Answer: A 🗳️
Explanation: Only visible for LatestCram members. You can sign-up / login (it's free).
The building in which the computer room is housed is required to have a sprinkler system. The building is therefore equipped with a wet pipe system.
What action, if any, should you recommend for the computer room?
- A. Replace the wet pipe system with a pre-action system.
- B. Maintain the current wet pipe system.
- C. Replace the wet pipe system with a deluge system.
- D. Replace the wet pipe system with a dry pipe system.
Correct Answer: A 🗳️
Explanation: Only visible for LatestCram members. You can sign-up / login (it's free).